HYUNDAI ENG
- HEATING Oil Temperature Controller -
Features
- Accurate temperature control system of the proportional control method (P.I.D) by function
- Indicating function of irregularities and alarm system
Distribution Diagram
External View
Standard Specifications
HEATING OIL STANDARD SPECIFICATIONS (140°C)
Classification | Unit | HD-20LO | HD-40LO | HD-60LO | HD-80LO | HD-100LO | |
---|---|---|---|---|---|---|---|
Medium | Oil | ||||||
Pump 60/50Hz |
Motor Capacity | kw(hp) | 0.33(0.45) | 0.75(1) | 1.1(1.5) | 1.5(2) | 1.5(2) |
Max Pump Head | m | 30 | |||||
Max Flow Rate | ℓ/min | 20 | 40 | 60 | 80 | 100 | |
Temp. Control Method | Control by P.I.D | ||||||
Heater Capacity | kw | 4 | 8 | 12 | 16 | 20 | |
Cooling Method | Indirect Cooling Method | ||||||
Pipe Size | Medium Pipe Size | 20A | 25A | 25A | 32A | 32A | |
Cooling Water Pipe Size | 15A | 15A | 15A | 15A | 15A | ||
Power Source | AC 3PH 220V, 380V±10%×60Hz/50Hz | ||||||
Alarm | Over Heating / Lack Medium / Pump Overload / Heater Trip / Phase-Reverse | ||||||
Dimension | L×W×H | mm | 940×430×800 | 940×430×850 | 940×500×850 | 940×500×850 | 1400×800×1600 |
Total Electric Power | kw | 4.33 | 8.75 | 13.1 | 17.5 | 21.5 |
HEATING OIL STANDARD SPECIFICATIONS (200°C)
Classification | Unit | HD-20LH | HD-40LH | HD-60LH | HD-80LH | HD-100LH | |
---|---|---|---|---|---|---|---|
Medium | (K-2120#) Heating Medium Oil | ||||||
Pump 60/50Hz |
Motor Capacity | kw(hp) | 0.33(0.45) | 0.75(1) | 1.1(1.5) | 1.5(2) | 1.5(2) |
Max Pump Head | m | 30 | |||||
Max Flow Rate | ℓ/min | 20 | 40 | 60 | 80 | 100 | |
Temp. Control Method | Control by P.I.D | ||||||
Heater Capacity | kw | 4 | 12 | 17 | 22 | 28 | |
Cooling Method | Indirect Cooling Method | ||||||
Pipe Size | Medium Pipe Size | 20A | 25A | 25A | 32A | 32A | |
Cooling Water Pipe Size | 15A | 15A | 15A | 15A | 15A | ||
Power Source | AC 3PH 220V, 380V±10%×60Hz/50Hz | ||||||
Alarm | Over Heating / Lack Medium / Pump Overload / Heater Trip / Phase-Reverse | ||||||
Dimension | L×W×H | mm | 940×430×800 | 940×430×800 | 940×500×850 | 940×500×850 | 1400×800×1600 |
Total Electric Power | kw | 4.33 | 12.75 | 18.1 | 23.5 | 29.5 |
HEATING OIL STANDARD SPECIFICATIONS (300°C)
Classification | Unit | HD-30LHH | HD-60LHH | HD-100LHH | HD-150LHH | |
---|---|---|---|---|---|---|
Medium | (K-2120#) Heating Medium Oil | |||||
Pump 60/50Hz |
Motor Capacity | kw(hp) | 1.1(1.5) | 2.2(3) | 3(4) | 4(5) |
Max Pump Head | m | 30 | ||||
Max Flow Rate | ℓ/min | 30 | 60 | 100 | 150 | |
Temp. Control Method | Control by P.I.D | |||||
Heater Capacity | kw | 13 | 25 | 42 | 63 | |
Cooling Method | Indirect Cooling Method | |||||
Pipe Size | Medium Pipe Size | 20A | 25A | 32A | 32A | |
Cooling Water Pipe Size | 15A | 15A | 15A | 15A | ||
Power Source | AC 3PH 220V, 380V±10%×60Hz/50Hz | |||||
Alarm | Over Heating / Lack Medium / Pump Overload / Heater Trip / Phase-Reverse | |||||
Dimension | L×W×H | mm | 930×430×850 | 930×430×850 | 1400×800×1600 | 1470×800×1600 |
Total Electric Power | kw | 14.1 | 27.2 | 45 | 67 |
- This product is subject to change without notice depending on technology development.
- In addition to the above products, we also order products according to special specifications.
- Power consumption changes depending on operating conditions.