Heating Water Temperature Controller

Feature

  • Accurate temperature control system of the proportional control
    method (P.I.D) by function.
  • Indicating function of irregularities and alarm system
  • Maximum discharge volume and maximum discharge pressure
    by the micro-mini power pump
  • High-precision temperature control(Deviation △T±0.5℃~0.8℃)

Distribution Diagram

계통도

External View

외형도

Standard Specifications

HEATING OIL STANDARD SPECIFICATIONS (90°C)

Classification Unit HD-20LW HD-40LW HD-60LW HD-80LW HD-100LW
Medium Wather
Pump
60/50Hz
Motor Capacity kw(hp) 0.37(1/2) 0.55(0.75) 0.75(1) 1.25(1.67) 1.25(1.67)
Max Pump Head m 30
Max Flow Rate ℓ/min 20 40 60 80 100
Temp. Control Method Control by P.I.D
Heater Capacity kw 4 8 12 16 20
Cooling Method Indirect Cooling Method
Pipe Size Medium Pipe Size 20A 25A 25A 32A 32A
Cooling Water Pipe Size 15A 15A 15A 15A 15A
Power Source AC 3PH 220V, 380V±10%×60Hz/50Hz
Alarm Over Heating / Lack Medium / Pump Overload / Heater Trip / Phase-Reverse
Dimension L×W×H mm 750×420×6500 750×420×650 920×430×800 920×550×1130 1000×550×1130
Total Electric Power kw 3.37 5.55 8.75 11.25 14.25

HEATING OIL STANDARD SPECIFICATIONS (140°C)

Classification Unit HD-20LHW HD-40LHW HD-60LHW HD-80LHW HD-100LHW
Medium Water
Pump
60/50Hz
Motor Capacity kw(hp) 0.33(0.45) 0.75(1) 1.1(1.5) 1.5(2) 1.5(2)
Max Pump Head m 30
Max Flow Rate ℓ/min 20 40 60 80 100
Temp. Control Method Control by P.I.D
Heater Capacity kw 4 8 12 16 20
Cooling Method Indirect Cooling Method
Pipe Size Medium Pipe Size 20A 25A 25A 32A 32A
Cooling Water Pipe Size 15A 15A 15A 15A 15A
Power Source AC 3PH 220V, 380V±10%×60Hz/50Hz
Alarm Over Heating / Lack Medium / Pump Overload / Heater Trip / Phase-Reverse
Dimension L×W×H mm 940×430×850 940×430×850 940×500×850 940×500×850 1400×800×1600
Total Electric Power kw 4.33 8.75 13.1 17.5 21.5

 

  • These products may change without notice depending on technology development.
  • Besides the products described above, products by special specifications are custom-made.
  • The criterion of the cooling capacity marked above is 60Hz, and when using 50Hz, you can apply 80% of the marked cooling capacity